tracker issue : CF-3772199

select a category, or use search below
(searches all categories and all time range)
Title:

Not supported error when installing

| View in Tracker

Status/Resolution/Reason: Closed/Fixed/

Reporter/Name(from Bugbase): Hank Miller / Hank Miller (nicxen)

Created: 06/06/2014

Components: Installation/Config, Connector

Versions: 11.0

Failure Type: Incorrect w/Workaround

Found In Build/Fixed In Build: CF11_Final /

Priority/Frequency: Trivial / Unknown

Locale/System: English / Solaris All

Vote Count: 0

Listed in the version 11.0.03.292480 Issues Fixed doc
Problem Description:
In /opt/coldfusion11/config/wsconfig/1/workers.properties file the last line "worker.cfusion.max_reuse_connections=250" is not supported on Solaris 11
Steps to Reproduce:
Install CF 11 on Solaris 11, try to start CF11. Check the error logs.
Actual Result:
CF11 will not start.
Expected Result:
CF11 to start
Any Workarounds:
Comment out the line worker.cfusion.max_reuse_connections=250 in /opt/coldfusion11/config/wsconfig/1/workers.properties

----------------------------- Additional Watson Details -----------------------------

Watson Bug ID:	3772199

Keywords:
FixTested


External Customer Info:
External Company:  
External Customer Name: nicxen
External Customer Email:  
External Test Config: My Hardware and Environment details:

Apache 2.2

Solaris 11

Attachments:

Comments:

ip restriction file should not be created on iis/apache connector installation iiprestrictions_file property should not be added to connector config file in IIS/Apache worker.cfusion.max_reuse_connections=250 should not be added to workers.properties file
Comment by Milan C.
11994 | October 28, 2014 12:05:52 AM GMT
Correcting my earlier comment: worker.cfusion.max_reuse_connections=250 will only be added in IIS workers.properties
Comment by Milan C.
11995 | October 31, 2014 05:25:24 AM GMT