Title:
Restart Required After Change of Memory Limit per Application for In-Memory Virtual File System.
| View in TrackerStatus/Resolution/Reason: Closed/Fixed/Fixed
Reporter/Name(from Bugbase): Mikeal P. / ()
Created: 03/01/2019
Components: Administrator, Administrator Console
Versions: 2016,2018
Failure Type: Non Functioning
Found In Build/Fixed In Build: 2016.0.07.311392 / CF2016U12,CF2018U5
Priority/Frequency: Normal / Some users will encounter
Locale/System: ALL / Win 2012 Server x64
Vote Count: 0
Problem Description:
If a change is made to the per application for In-Memory Virtual File system setting and the server is not restarted, the setting will not be reflected during runtime.
Steps to Reproduce:
Change the Memory Limit per Application for In-Memory Virtual File System and do not reboot.
Actual Result:
Server changes are not reflected before restart.
Expected Result:
Server changes should take affect since it is not documented that they will not.
Any Workarounds:
Restart the coldfusion server after change.
Attachments:
Comments: