Title:

Restart Required After Change of Memory Limit per Application for In-Memory Virtual File System.

| View in Tracker

Status/Resolution/Reason: Closed/Fixed/Fixed

Reporter/Name(from Bugbase): Mikeal P. / ()

Created: 03/01/2019

Components: Administrator, Administrator Console

Versions: 2016,2018

Failure Type: Non Functioning

Found In Build/Fixed In Build: 2016.0.07.311392 / CF2016U12,CF2018U5

Priority/Frequency: Normal / Some users will encounter

Locale/System: ALL / Win 2012 Server x64

Vote Count: 0

Problem Description:
If a change is made to the per application for In-Memory Virtual File system setting and the server is not restarted, the setting will not be reflected during runtime.

Steps to Reproduce:
Change the Memory Limit per Application for In-Memory Virtual File System and do not reboot.

Actual Result:
Server changes are not reflected before restart.

Expected Result:
Server changes should take affect since it is not documented that they will not.

Any Workarounds:
Restart the coldfusion server after change.

Attachments: