Status/Resolution/Reason: Closed/Fixed/
Reporter/Name(from Bugbase): Nathan Strutz / Nathan Strutz (Nathan Strutz)
Created: 02/11/2016
Components: Administrator
Versions: 11.0
Failure Type:
Found In Build/Fixed In Build: CF11_Final /
Priority/Frequency: Minor / Some users will encounter
Locale/System: ALL / Windows 7
Vote Count: 0
Problem Description: When setting the client variable purge time to more than 596 hours, the server interprets that as zero hours. Nothing in the user interface indicates that there is a maximum value for the Client Variable Purge Interval hour field, nor that I had overrun it. A related error is given to the console: "Warning [http-bio-80-exec-3] - Using default Client Variable Purge Interval of 1 hour 7 minutes, interval supplied is too short: 7 minutes."
Steps to Reproduce:
- Log in to ColdFusion Administrator
- Click to Client Variables
- Change Purge Interval "hours" field to 999
Actual Result:
Purge interval is executed on the default schedule - 1 hour, 7 minutes.
Expected Result:
Purge interval should be executed every 999 hours, 7 minutes, or the screen should return an error explaining the maximum.
Any Workarounds:
Set the purge interval hour to less than 597 hours.
----------------------------- Additional Watson Details -----------------------------