Title:
Please enable some form of metrics/monitoring for the CF10/11 web server connector pooling
| View in TrackerStatus/Resolution/Reason: To Fix//Investigate
Reporter/Name(from Bugbase): Charlie Arehart / Charlie Arehart (Charlie Arehart)
Created: 06/30/2014
Components: Installation/Config, Connector
Versions: 11.0
Failure Type: Enhancement Request
Found In Build/Fixed In Build: CF11_Final /
Priority/Frequency: Trivial / Unknown
Locale/System: English / Win 2008 Server
Vote Count: 18
Please enable some form of metrics/monitoring for the CF10/11 web server connector pooling, something that would report in CF how many connections are currently open in the connectory, and for how long.
This information could be reported in the form of a page in the CF Admin, or via logging or a metrics command-line tool (or both). While someone may be tempted to put it in the CF Server Monitor, that will not help those using CF Standard, and this problem is too important for this information to be lost and viewable only in the monitor (unless, again, you may do it in logging or a command-line tool AS WELL).
Right now, we are operating in the dark, having to go on recommendations in Adobe CF Team blog entries to guess at what may be good values, for changes in the worker properties:
worker.cfusion.max_reuse_connections
worker.cfusion.connection_pool_size
worker.cfusion.connection_pool_timeout
and the server.xml maxthreads value on the Connector element.
As I have discussed in another feature request I just posted (https://bugbase.adobe.com/index.cfm?event=selectBug&CFGRIDKEY=3783361), many people are having issues with the default values for the web server connector settings in CF 10 and 11, so much so that Adobe has created blog entries for CF10 and 11 recommending changes (which I point to there)..
If instead we had insight into the connections, we could then be far better-informed to help improve the settings.
Better still, if these metrics were tracked/exposed in CF, then perhaps an additional feature could be to offer warnings for when these limits are being reached, and perhaps even take action (restarting a hung connector) or better yet, make recommendations as to better values that should be chosen.
----------------------------- Additional Watson Details -----------------------------
Watson Bug ID: 3783364
External Customer Info:
External Company:
External Customer Name: carehart
External Customer Email:
External Test Config: Not unique to any one configuration
Attachments:
Comments: