Status/Resolution/Reason: Closed/Withdrawn/NotABug
Reporter/Name(from Bugbase): Susan Hurst / Susan Hurst (Susan Hurst)
Created: 06/22/2016
Components: Administrator
Versions: 11.0
Failure Type: Non Functioning
Found In Build/Fixed In Build: CF11_Final /
Priority/Frequency: Trivial / Unknown
Locale/System: English / Win 2012 Server x64
Vote Count: 0
Problem Description: When I install update 8 on my server 2012r2 system and try to go to the ColdFusion Administrator I receive the following error: http status 500 - coldfusion.server.ServiceFactory$ServiceNotAvailableException: The Runtime service is not available.
Steps to Reproduce: System was running ColdFusion 11 Update 7 with JDK Version 1.8.0_92 and ColdFusion Administrator works correctly. Once I install ColdFusion 11 Update 8 using Administrative privileges, I get the above error when trying to get to the Administrator. There are no issues in the installation in the Update 8 in the log. Also replaced the tools.jar file from JDK Version 1.8.0_92 since that was what was required in the instruction for JDK 1.8.0_72.
Actual Result: ColdFusion 11 administrator breaks
Expected Result: ColdFusion 11 Administrator works
Any Workarounds: None
----------------------------- Additional Watson Details -----------------------------
Watson Bug ID: 4166953
External Customer Info:
External Company:
External Customer Name: Susan Hurst
External Customer Email:
External Test Config: My Hardware and Environment details: Windows Server 2012r2 using IE 11 patched to the latest updates.
Attachments:
- June 27, 2016 00:00:00: 1_coldfusion-out-log.txt
Comments: