[regression] System Probe not working. HTTP request returned non-200 status code:Connection Failure

| View in Tracker

Status/Resolution/Reason: Closed/Fixed/

Reporter/Name(from Bugbase): / ext-user (Vishal Jaswal)

Created: 09/01/2014

Components: Administrator, System Probes

Versions: 11.0

Failure Type: Unspecified

Found In Build/Fixed In Build: 290107 / CF10 Update16

Priority/Frequency: Normal / Unknown

Locale/System: English / Mac 10 All,Win XP All

Vote Count: 0

Listed in the version 11.0.03.292480 Issues Fixed doc
Problem: System Probe not working. HTTP request returned non-200 status code:Connection Failure

Method: Create System Probe in CF 11 (11,0,0,290107 ). While running getting HTTP request returned non-200 status code:Connection Failure

Result: HTTP request returned non-200 status code:Connection Failure. Status code unavailable

Expected: System probe should work as it is working fine in CF 10 ( 	10,0,13,287689 )

Workaround: NA

----------------------------- Additional Watson Details -----------------------------

Watson Bug ID:	3816133

External Customer Info:
External Company:  
External Customer Name:  
External Customer Email:

Attachments:

Comments:

Verified this is fixed in CF11 Update 3 (build 11,0,03,292024(PreRelease)). Thanks!, -Aaron
Comment by External U.
11172 | November 08, 2014 12:03:55 AM GMT
The fix for this bug is available in the pre-release build of ColdFusion 10 Update 16
Comment by CFwatson U.
11173 | February 20, 2015 09:22:19 AM GMT